Installation and Usage:
1.When the power supply is cut off due to power outage or other reasons, the output of the two sides can be temporarily maintained under controlled conditions.
2.The cable is a four-core cable. When the monitor output (analog output, switch output) is not used, it may cause malfunction, so it must be avoided from contact with other cables.
3.The cable has a built-in positioning groove. When locking, tighten the outer nut and do not rotate the body to avoid damaging the connector.
4.At the time of shipment, the product has been adjusted according to the product specifications. It is strictly forbidden to disassemble it privately, as it may cause malfunctions.
Specifications
Model |
ERV2-1 |
ERV2-5 |
Minimum supply pressure |
Set pressure +01MPa |
|
Maximum supply pressure |
0.2MPa |
1.0MPa |
Set pressure range |
0MPa~0.1MPa |
0MPa~1.0MPa |
Supply voltage |
24V DC±10% |
|
Current consumption |
0.12A or less |
|
Linearity |
Within 1%F.S |
|
Hysteresis |
Within 0.5%F.S |
|
Repeatability |
Within 0.5%F.S |
|
Operating temperature range |
0℃~50℃ |
|
Protection level |
IP65 |