Specifications
Model |
Nominal diameter |
Connecting thread |
Work Pressure (MPa) |
Ambient temperature |
Medium temperature |
Kv value m³/h |
Power consumption |
Switching frequency (Hz) |
Standard voltage |
||
AC(VA) |
DC(W) |
||||||||||
SB116-2A 1008 |
10mm |
G1/4 |
0~1.0MPa |
-10~+55℃ |
-10~+90℃ |
1.4 |
20 |
13 |
≥1Hz |
12V DC 24V DC 24V AC 36V AC 110V AC 220V AC 380V AC +10% |
|
SB116-2A 1010 |
10mm |
G3/8 |
1.4 |
20 |
13 |
≥1Hz |
|||||
SB116-2A 1015 |
10mm |
G1/2 |
1.4 |
20 |
13 |
≥1Hz |
|||||
SB116-2A 1415 |
14mm |
G1/2 |
2.52 |
20 |
13 |
≥0.5Hz |
|||||
SB116-2A 1420 |
14mm |
G3/4 |
2.52 |
20 |
13 |
≥0.5Hz |
|||||
SB116-2A 2020 |
20mm |
G3/4 |
5.0 |
20 |
13 |
≥0.5Hz |
|||||
SB116-2A 2025 |
20mm |
G1 |
5.0 |
20 |
13 |
≥0.5Hz |
Model |
Nominal diameter |
Connecting thread |
Work Pressure (MPa) |
Ambient temperature |
Medium temperature |
Kv value m³/h |
Power consumption |
Switching frequency (Hz) |
Standard voltage |
||
AC(VA) |
DC(W) |
||||||||||
SB116-2B 1008 |
10mm |
G1/4 |
0.02~1.0MPa |
-10~+55℃ |
-10~+90℃ |
1.4 |
20 |
13 |
≥1Hz |
12V DC 24V DC 24V AC 36V AC 110V AC 220V AC 380V AC +10% |
|
SB116-2B 1010 |
10mm |
G3/8 |
1.4 |
20 |
13 |
≥1Hz |
|||||
SB116-2B 1015 |
10mm |
G1/2 |
1.4 |
20 |
13 |
≥1Hz |
|||||
SB116-2B 1415 |
14mm |
G1/2 |
2.52 |
20 |
13 |
≥0.5Hz |
|||||
SB116-2B 1420 |
14mm |
G3/4 |
2.52 |
20 |
13 |
≥0.5Hz |
|||||
SB116-2B 2020 |
20mm |
G3/4 |
0.02~1.6MPa |
5.0 |
20 |
13 |
≥0.5Hz |
||||
SB116-2B 2025 |
20mm |
G1 |
0.02~1.6MPa |
5.0 |
20 |
13 |
≥0.5Hz |
||||
SB116-2B 4035 |
40mm |
G1-1/4 |
0.025~1.6MPa |
18 |
20 |
13 |
≥0.33Hz |
||||
SB116-2B 4040 |
40mm |
G1-1/2 |
18 |
20 |
13 |
≥0.33Hz |
|||||
SB116-2B 5050 |
50mm |
G2 |
28 |
20 |
13 |
≥0.33Hz |
Model |
Nominal diameter |
Connecting thread |
Work Pressure (MPa) |
Ambient temperature |
Medium temperature |
Kv value m³/h |
Power consumption |
Switching frequency (Hz) |
Standard voltage |
||
AC(VA) |
DC(W) |
||||||||||
SB116-4 1308 |
13mm |
G1/4 |
0.1~1.6 MPa |
-20~+55℃ |
0~+180℃ |
3.6 |
20 |
13 |
≥1Hz |
12V AC 24V AC 24V AC 36V AC 110V AC 220V AC 380V AC +10% |
|
SB116-4 1310 |
13mm |
G3/8 |
3.6 |
20 |
13 |
≥1Hz |
|||||
SB116-4 1315 |
13mm |
G1/2 |
3.6 |
20 |
13 |
≥1Hz |
|||||
SB116-4 2520 |
25mm |
G3/4 |
11 |
20 |
13 |
≥0.5Hz |
|||||
SB116-4 2525 |
25mm |
G1 |
11 |
20 |
13 |
≥0.5Hz |
Model |
Nominal diameter |
Connecting thread |
Work Pressure (MPa) |
Ambient temperature |
Medium temperature |
Kv value m³/h |
Power consumption |
Switching frequency (Hz) |
Standard voltage |
||
AC(VA) |
DC(W) |
||||||||||
SB116-5 1308 |
13mm |
G1/4 |
0.1~4.0 MPa |
-20~+55℃ |
0~+90℃ |
2.52 |
20 |
13 |
≥1Hz |
12V DC 24V DC 24V DC 36V AC 110V AC 220V AC 380V AC +10% |
|
SB116-5 1310 |
13mm |
G3/8 |
2.52 |
20 |
13 |
≥1Hz |
|||||
SB116-5 1315 |
13mm |
G1/2 |
2.52 |
20 |
13 |
≥1Hz |
|||||
SB116-5 2520 |
25mm |
G3/4 |
5.0 |
20 |
13 |
≥0.5Hz |
|||||
SB116-5 2525 |
25mm |
G1 |
8.5 |
20 |
13 |
≥0.5Hz |