3/2 Directional Control Valve 3V200 4V200

3V200 4V200 series of NC NO 3/2 5/3 directional control solenoid valves 12VDC 24VDC 110VAC 220VAC

Features

HANUMAN Services

HANUMAN can offer you with 3V200 and 4V200 series of 3-way and 5-way solenoid valves or 3/2 directional control valves with terminal DIN43650b and flying leads types of connection, 12 VDC to 220 VAC, 1/8” and 1/4” port sizes.

3V200 and 4V200 series of 5/3-way solenoid valves can totally be on a par with airtac valve 4v210-08.

Specifications

Model

4V210-06

4V220-06

4V230C-06

4V230E-06

4V230P-06

4V210-08

4V220-08

4V230C-08

4V230E-08

4V230P-08

Position

Two-position five-way

Three-position five-way

Two-position five-way

Three-position five-way

Effective area

14 mm2(CV=0.78 m3/h)

12 mm2(CV=0.67 m3/h)

16 mm2(CV=0.89 m3/h)

12 mm2(CV=0.67 m3/h)

 

Model

3V210-06

3V220-06

3V210-08

3V220-08

Position

Two-position three-way

Effective area

14 mm2(CV=0.78 m3/h)

16 mm2(CV=0.89 m3/h)

Port size

IN=OUT=EXHAUST=G1/8”

IN=OUT=G1/4” EXHAUST=G1/8”

Fluid

Air

Action

Internal pilot

Operating pressure range

 

0.15 to 0.8 MPa

 

Proof pressure

1.2 MPa

Operating temperature range

-5 to 50 ℃

Rated voltage

24 VDC, 220 VAC

Power consumption

4.5 VA, 3 W

Insulation class

F

Protection class

IP65

Electrical entry

Flying leads, terminal DIN

Max. frequency

5 Hz

Shortest excitation time

0.05 S

Installation note

I. The model and parameter printed on the label shall be checked that whether they are totally conforming with the actual technical requirements or not.

II. The valve body, solenoid coil, plunger, and DIN43650 connector shall be ensured with no damages.

III. The pipeline shall be ensured clean, otherwise relative filtering devices shall be installed on the pipeline.

IV. The valve port shall be connected with pipeline according to the direction arrowhead indicated (same to the fluid flow direction), and the connection seals are in good condition.

V. The best installation method is perpendicular to pipeline and keep solenoid coil upward. The maximum inclination angle should be less than 30°, otherwise the normal operation can not be ensured.

VI. When the solenoid valve is installed outdoors, the protective cover is necessary to make sure its performance and long service life.

Attention

I. The solenoid coil shall not be covered when it is powered in order to avoid overheating or even burnout.

II. Do not touch the working solenoid coil because of its high temperature.

III. Do not hit and knock the solenoid valve.

IV. All the application scenarios shall be in the range of solenoid valve technical data.